This regulation establishes physical plant and life safety standards for apartment complexes owned by behavioral health providers licensed under the Alabama Department of Mental Health. Operators must comply with NFPA 101 Life Safety Code (Apartment Buildings Chapter), the International Building Code, and the National Electrical Code for both existing and new construction. Specific requirements cover fire suppression and alarm systems, smoke detectors, means of egress, emergency lighting, hallway and ceiling dimensions, door specifications, stair construction, and porch/landing guardrails.

View official source
Regulation text
Ala. Admin. Code r. 580-3-22-.14 - Apartment Complexes 

 State Regulations 

 Compare

Apartment complexes which are owned by providers shall adhere
 to the most current edition of the NFPA 101, 
Life Safety Code,
 Apartment Buildings Chapter,
 International Building Code and National
 Electrical Code. Plans to construct new apartment complexes shall adhere to the
 NFPA 101, 
Life Safety Code, Apartment Buildings Chapter,

 International Building Code and National Electrical Code. These plans will be
 reviewed by the Office of Life Safety and Technical Services.

(1)

FIRE SAFETY EQUIPMENT

(a)
 Apartment complex buildings shall be
 protected throughout with an approved, supervised automatic sprinkler system
 unless one of the following exceptions or met: 
 
1.
 Exit door opening directly to the street
 or yard at ground level from each dwelling unit.

2.
 Direct access to an outside stair serving
 a maximum of two units located on the same floor from each dwelling
 unit.

3.
 Direct access to an
 interior stairs serving only that dwelling unit and separated form all other
 portions of the building by a fire barrier having a 1 hour resistance rating
 with no opening therein.

(b)
 Apartment complex buildings with more
 than three stories or more than 11 dwelling units shall be protected with a
 fire alarm system in accordance with 
Section
 9.6,
 unless one of the following exceptions are met: 
 
1.
 Each dwelling unit is separated from other
 contiguous dwelling units by a fire barrier of not less than 1 hour and where
 each dwelling unit has either it own independent exit or it own independent
 stairway or ramp discharging at grade.

2.
 Building protected by an automatic
 sprinkler system, not exceeding 4 stories in height and containing not more
 than 16 dwelling units.

(c)
 Electric smoke detectors shall be
 installed outside every sleeping area in the immediate vicinity of the bedrooms
 and on all levels of the dwelling unit, including basements and in bedrooms of
 dwelling units unless apartment complex is protected throughout by an approved,
 supervised automatic sprinkler system.

(d)
 Smoke detectors shall be mounted on
 ceilings where possible and only allowed on walls when impossible for ceiling
 mounting. Detectors on walls shall be mounted with top of detector not less
 than 4 inches nor more than 12 inches from ceiling.

(e)
 Smoke detectors shall not be located
 under or within 3 feet of ceiling fan blades or air supply diffusers or
 returns.

(f)
 Portable fire
 extinguishers in accordance with Section 9.7.4.1 shall be provided in hazardous
 areas, unless the building is protected throughout with an approved supervised
 automatic sprinkler system.

(2)

MEANS OF EGRESS COMPONENTS

(a)
 Any building that is protected throughout
 by an approved, supervised automatic sprinkler system install in accordance
 with Section 30.3.5., has four or fewer stories, and has not more than four
 dwelling units per story shall be permitted to have a single exit, provided
 that all of the following conditions apply:
1.

 The stairway is separated from the rest of the building by barriers having not
 less than a 1-hour fire resistance rating, with self-closing 1-hour fire door
 assemblies protecting all openings between the stairway enclosure and the
 building.

2.
 The stairway does not
 serve more than one-half story below the level of exit discharge.

3.
 All corridors serving as access to exits
 have a minimum 1-hour fire resistance rating.

4.
 There is not more than 35 ft of travel
 distance from the entrance door of any dwelling unit to an exit.

5.
 One-half-hour fire-rated horizontal and
 vertical separation between dwelling units is provided.

(b)
 Emergency lighting in accordance with
 Section 7.9 shall be provided in all buildings with 12 dwelling units, or of
 more than 3 stories in height, unless every dwelling unit has a direct exit to
 the outside of the building at grade level.

(c)
 Means of egress shall have signs in
 accordance with Section 7.10 in all buildings requiring more than one
 exit.

(3)

ROOM
 CEILINGS AND HALLWAYS

(a)
 The width of
 hallways shall be not less than 36 inches and the height not less than 7 feet 6
 inches.

(b)
 The height of room
 ceilings shall not be less than 7 feet 6 inches.

(c)
 Existing facilities which fit the
 definition of this code will not be subject to the minimum ceiling height as
 stated.

(4)

DOORS

(a)
 Doors in the path of
 travel to the means of escape shall be not less than 28 inches wide and not
 less than 6 feet 8 inches high. 
 
Bathrooms and closet doors shall be not less than 24 inches
 wide.

(b)
 Doors on
 facilities with physically disabled persons must comply with ADA
 standards.

(c)
 Doors shall not have
 more than 2 locking devices.
1.
 No double key
 dead bolt locks are allowed.

(5)

STAIRS

(a)
 Stairs serving as a required means of
 escape shall be of permanent fixed construction and shall have handrails on
 both sides of the steps that are not less than 34 inches nor more than 38
 inches above the surface of the tread.

(b)
 In new construction, the minimum height
 of risers must be a minimum of 4 inches and maximum of 7 inches in height, and
 a minimum tread depth of 11 inches.

(c)
 In existing construction, the maximum
 height of risers must be 8 inches and the minimum tread depth must be 9
 inches.

(d)
 Stairs must be uniform
 in design.

(6)

PORCHES AND LANDINGS

(a)
 Porches
 and landings shall have guardrails not less than 42 inches high when any
 portion of the porch or landing equals or exceeds 24 inches above ground
 level.

(b)
 Open guards, other than
 approved existing open guards, shall have rails or an ornamental pattern such
 that an object 4 inches in diameter is not able to pass through any opening up
 to a height of 34 inches.

Notes

Ala. Admin. Code
 r. 
580-3-22-.14

New Rule: Filed November
 21, 2008; effective December 26, 2008.

Author:
 DMH/MR Office of Life Safety and
 Technical Services

Statutory Authority:

Code of Ala.
 1975,

 §
 
22-50-11
.