§483.90(e)(1)(ii) Measure at least 80 square feet per resident in multiple resident

Jurisdiction: CM Agency: Centers for Medicare & Medicaid Services
SNF (100%)
Plain-English summary

This regulation establishes minimum bedroom square footage requirements for nursing facility residents: at least 80 square feet per resident in multi-resident rooms and at least 100 square feet in single-occupancy rooms. Usable living space is calculated from floor measurements excluding fixed features such as toilets, baths, closets, and alcoves, but including door swing arcs and minimal protrusions. Surveyors are directed to carry tape measures and verify compliance, with variations permitted only if separately approved under §483.90(e)(3).

View official source
Regulation text
F912
(Rev. 173, Issued: 11-22-17, Effective: 11-28-17, Implementation: 11-28-17) 
 
§483.90(e)(1)(ii) Measure at least 80 square feet per resident in multiple resident 
bedrooms, and at least 100 square feet in single resident rooms; 
 
GUIDANCE: §483.90(e)(1)(ii) 
See §483.90(e)(3) regarding variations. 

The measurement of the square footage should be based upon the useable living space of 
the room. Therefore, the minimum square footage in resident rooms should be measured 
based upon the floor’s measurements exclusive of toilets and bath areas, closets, lockers, 
wardrobes, alcoves, or vestibules. However, if the height of the alcoves or vestibules 
reasonably provides useful living area, then the corresponding floor area may be included 
in the calculation. 
 
The space occupied by movable wardrobes should be excluded from the useable square 
footage in a room unless it is an item of the resident’s own choice and it is in addition to 
the individual closet space in the resident’s room. Non-permanent items of the resident’s 
own choice should have no effect in the calculation of useable living space. 
 
Protrusions such as columns, radiators, ventilation systems for heating and/or cooling 
should be ignored in computing the useable square footage of the room if the area 
involved is minimal (e.g., a baseboard heating or air conditioning system or ductwork 
that does not protrude more than 6 to 8 inches from the wall, or a column that is not more 
than 6 to 8 inches on each side) and does not have an adverse effect on the resident’s 
health and safety or does not impede the ability of any resident in that room to attain his 
or her highest practicable well-being. If these protrusions are not minimal they would be 
deducted from useable square footage computed in determining compliance with this 
requirement. 
 
The swing or arc of any door which opens directly into the resident’s room should not be 
excluded from the calculations of useable square footage in a room. 
 
PROCEDURES: §483.90(e)(1)(ii) 
The facility layout may give square footage measurements. Carry a tape measure and take 
measurements if the room appears small. 
 
PROBES: §483.90(e)(1)(ii) 
Unless a variation has been applied for and approved under §483.90(e)(3), are there at 
least 80 square feet per resident in multiple resident rooms and at least 100 square feet for 
single resident rooms?