ARSD 44:78 INPATIENT CHEMICAL DEPENDENCY TREATMENT FACILITY

Jurisdiction: SD Agency: South Dakota Department of Social Services, Division of Behavioral Health (also Dept. of Health; Dept. of Human Services)
DETOX (100%) SUD_RESIDENTIAL (100%)
Plain-English summary

This South Dakota regulation (ARSD 44:78) establishes comprehensive licensing and operating standards for inpatient chemical dependency treatment facilities, classified as ASAM Level III.7 medically-monitored intensive inpatient treatment programs. Facility operators must comply with requirements covering licensure procedures, physical environment and safety (patient rooms, care units, food service, sanitation, utilities), fire safety, and construction standards. Operators must also meet reporting obligations for abuse, neglect, patient deaths, missing patients, and facility closures, and must maintain ongoing personnel training programs.

View official source
Regulation text
ARTICLE

44:78

INPATIENT
CHEMICAL DEPENDENCY TREATMENT FACILITY

Chapter

44:78:01
 Rules of general
applicability.

44:78:02
 Physical
environment and safety.

44:78:03
 Fire safety and
construction standards.

CHAPTER

44:78:01

RULES OF GENERAL
APPLICABILITY

Section

44:78:01:01
 Definitions.

44:78:01:02
 Licensure
of inpatient chemical dependency treatment facilities.

44:78:01:03
 Name
of facility.

44:78:01:04
 Bed
capacity.

44:78:01:05
 Joint
occupancy.

44:78:01:06
 Reports.

44:78:01:07
 Plans
of correction.

44:78:01:08
 Modifications.

44:78:01:09
 Scope
of article.

44:78:01:10
 Scope
of licensure inspections.

Rule 44:78:01:01 Definitions.

44:78:01:01. Definitions.

Terms defined in SDCL 
34-12-1.1
 have the same meaning in this article. In addition, terms used in this article mean:

 (1) "Abuse,"
an intentional act toward an individual indicating that one or more of the
following has occurred:

 (a) A
criminal conviction against a person for mistreatment toward an individual; or

 (b) In
the absence of a criminal conviction, substantial evidence that one or more of
the following has occurred resulting in harm, pain, fear, or mental anguish:

 (i) Misappropriation
of a patient's or resident's property or funds;

 (ii) An
attempt to commit a crime against a patient or resident;

 (iii) Physical
harm or injury against a patient or resident; or

 (iv) Using
profanity, making a gesture, or engaging in other any act made to or directed
at a patient or resident;

 (2) "Administrator,"
a person appointed by the owner or governing body of a facility who is
responsible for the daily overall management of the facility and who maintains
an office on the premises of the facility;

 (3) "Department,"
the South Dakota Department of Health;

 (4) "Developmental
disability," a severe, chronic disability of a person as defined in SDCL 
27B-1-18
 or a disability which:

 (a) Is
attributable to a mental or physical impairment or combination of mental and
physical impairments;

 (b) Is
manifested before the person attains age 22;

 (c) Is
likely to continue indefinitely;

 (d) Results
in substantial functional limitations in three or more of the following areas
of major life activity:

 (i) Self-care;

 (ii) Receptive
and expressive language;

 (iii) Learning;

 (iv) Mobility;

 (v) Self-direction;

 (vi) Capacity
for independent living; and

 (vii) Economic
self-sufficiency; and

 (e) Reflects
the person's need for an array of generic services, met through a system of
individual planning and supports over an extended time, including those of a
life-long duration;

 (5) "Exploitation,"
the wrongful taking or exercising of control over property of a person with
intent to defraud that person;

 (6) "Facility,"
the place of business used to provide health care for patients that is licensed
by the department;

 (7) "Governing
body," is an individual, partnership, or an organized body of persons that
is ultimately responsible for the quality of care in an inpatient chemical
dependency treatment facility, credentialing of and granting privileges to the
medical staff, maintaining the financial viability of the facility, and
formulating institutional policies and procedures, or bylaws governing the
operation of the facility;

 (8) "Healthcare
worker," any paid person working in a healthcare setting;

 (9) "Licensed
health professional," a physician; physician's assistant; nurse
practitioner; physical, speech, or occupational therapist; physical or
occupational therapy assistant; nurse; nursing facility administrator;
dietitian; pharmacist; respiratory therapist; or social worker who holds a
current license to practice in South Dakota;

 (10) "Medical
staff," an organized staff composed of practitioners that operates under
bylaws approved by the governing body and which is responsible for reviewing
the qualifications of practitioners applying for clinical privileges and for
the provision of medical care to patients and residents in a health care
facility;

 (11) "Neglect,"
harm to a person's health or welfare, without reasonable justification, caused
by the conduct of someone responsible for the person's health or welfare,
including but not limited to offensive behavior made to or directed at a
client, and the failure to provide timely, consistent, and safe services,
treatment, or care necessary to avoid physical harm, mental anguish, or mental
illness to the person;

 (12) "Patient,"
a person with a valid order by a practitioner for diagnostic or treatment
services in a chemical dependency treatment facility;

 (13) "Patient
advocate," an agency responsible for the protection and advocacy of
patients, including the department, the state ombudsman, the protection and
advocacy network, and the Medicaid fraud control unit; and

 (14) "Qualified
personnel," persons with the specific education, license, and training to
provide the health service for which they are employed.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13.

Law
Implemented:
 SDCL 
34-12-13.

Rule 44:78:01:02 Licensure of inpatient chemical dependency treatment facilities.

44:78:01:02. Licensure
of inpatient chemical dependency facility.
 Any license issued shall denote
the name of the facility and the facility address on the face of the license.
The license shall include each facility address at which services licensed under
this chapter are provided. The most current license issued by the department
shall be posted on the premises of the facility in a place conspicuous to the
public. The license certificate remains the property of the department.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-7.

Law
Implemented:
 SDCL 
34-12-7.

Rule 44:78:01:03 Name of facility.

44:78:01:03. Name
of facility.
 Each facility shall be designated by a pertinent and
distinctive name that shall be used in applying for a license. The name may not
be changed without first notifying the department in writing. No facility may
be given a name or advertise in a way that implies services rendered are in
excess of the classification for which it is licensed or which would indicate
an ownership other than actual.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-7.

Law
Implemented:
 SDCL 
34-12-7

Rule 44:78:01:04 Bed capacity.

44:78:01:04. Bed
capacity.
 The department shall establish the bed capacity of each facility
pursuant to the physical plant and space provisions of this article. The
patient census may not exceed the bed capacity for which the facility is
licensed. A request by the facility for an adjustment in bed capacity because
of change of purpose or construction shall be approved by the department before
any changes are made.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-7.

Law
Implemented:
 SDCL 
34-12-7.

Rule 44:78:01:05 Joint occupancy.

44:78:01:05.
 Joint occupancy.
 The use of a portion of a building for a purpose
other than that covered by the license may be approved by the department only
if it can be shown that joint occupancy is not detrimental to the welfare of
the patients. The area shall be open to inspection by the department.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
 and (3).

Law
Implemented:
 SDCL 
34-12-13(1)
 and (3).

Rule 44:78:01:06 Reports.

44:78:01:06. Reports.

Each facility shall fax, email, or mail to the department the pertinent data
necessary to comply with the requirements of all applicable administrative
rules and statutes.

 Any
incident or event where there is reasonable cause to suspect abuse or neglect
of any patient by any person shall be reported within 24 hours of becoming
informed of the alleged incident or event. The facility shall report each
incident or event orally or in writing to the state's attorney of the county in
which the facility is located, to the Department of Social Services, or to a
law enforcement officer. The facility shall report each incident or event to
the department within 24 hours, and conduct a subsequent internal investigation
and provide a written report of the results to the department within five
working days after the event.

 Each
facility shall report to the department within 48 hours of the event any death
resulting from other than natural causes originating on facility property such
as accidents or suicide. The facility shall conduct a subsequent internal
investigation and provide a written report of the results to the department
within five working days after the event.

 Each
facility shall report a missing patient to the department within 48 hours. The
facility shall conduct a subsequent internal investigation and provide a
written report of the results to the department within five working days after
the event.

 Each
facility shall also report to the department as soon as possible any fire with
damage or where injury or death occurs; any partial or complete evacuation of
the facility resulting from natural disaster; or any loss of utilities, such as
electricity, natural gas, telephone, emergency generator, fire alarm,
sprinklers, and other critical equipment necessary for operation of the
facility for more than 24 hours.

 Each
facility shall notify the department of any anticipated closure or
discontinuation of service at least 30 days in advance of the effective date.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(14).

Law
Implemented:
 SDCL 
34-12-13(14).

Rule 44:78:01:07 Plans of correction.

44:78:01:07. Plans
of correction.
 Within 10 days of the receipt of the statement of
deficiencies, each facility shall submit to the department a written plan of
correction for a citation of noncompliance with licensure requirements. The
plan of correction shall be signed, dated, and on forms provided by the
department. The department may reject the plan of correction if there is no
evidence the plan will cause the treatment facility to attain or maintain
compliance with SDCL chapter 
34-12
 and this article.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(5).

Law
Implemented:
 SDCL 
34-12-13(5).

Rule 44:78:01:08 Modifications.

44:78:01:08. Modifications.

A modification specified by this section may be requested in writing by the
facility.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(5)
 and (14).

Law
Implemented:
 SDCL 
34-12-13(5)
 and (14).

Rule 44:78:01:09 Scope of article.

44:78:01:09. Scope
of article.
 Nothing in article 44:78 limits or expands the rights of any
healthcare worker to provide services within the scope of the professional's
license, certification, or registration, as provided by South Dakota law.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(5).

Law
Implemented:
 SDCL 
34-12-13(5).

Rule 44:78:01:10 Scope of licensure inspections.

44:78:01:10. Scope
of licensure inspections.
 Inpatient chemical dependency treatment
facilities are Level III.7 medically-monitored intensive inpatient treatment
programs providing services in accordance with article 46:05. The department's
scope of inspection of these facilities includes licensure, physical
environment and safety, fire safety, construction standards, and accessibility.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
, (2), (3), (5), and (14).

Law
Implemented:
 SDCL 
34-12-13(1)
, (2), (3), (5), and (14).

CHAPTER

44:78:02

PHYSICAL
ENVIRONMENT AND SAFETY

Section

44:78:02:01
 Sanitation.

44:78:02:02
 Cleaning
procedures.

44:78:02:03
 Patient
rooms.

44:78:02:04
 Patient
room furnishings.

44:78:02:05
 Care
units.

44:78:02:06
 Food
service.

44:78:02:07
 Laundry.

44:78:02:08
 Storage.

44:78:02:09
 Outside
yard storage.

44:78:02:10
 Flooring.

44:78:02:11
 Handwashing
fixtures.

44:78:02:12
 Exhaust
ventilation.

44:78:02:13
 Waste
disposal.

44:78:02:14
 Ventilation.

44:78:02:15
 Heating
and cooling.

44:78:02:16
 Hot
water systems.

44:78:02:17
 Potable
water.

44:78:02:18
 Water
supply.

44:78:02:19
 Plumbing.

44:78:02:20
 Lighting.

44:78:02:21
 Electrical
convenience outlets.

44:78:02:22
 Infection
control.

44:78:02:23
 Occupant
protection.

44:78:02:24
 Physical
plant changes.

44:78:02:25
 Insect
and rodent control.

44:78:02:26
 Location.

44:78:02:27
 Preventative
maintenance.

44:78:02:28
 Other
hazardous conditions.

44:78:02:29
 Personnel
training.

Rule 44:78:02:01 Sanitation.

44:78:02:01. Sanitation.

The facility shall be kept clean, neat, and free of litter and rubbish.
Hazardous cleaning solutions, chemicals, and poisons shall be labeled, stored
in a safe place, and kept in an enclosed cabinet. Garbage and refuse shall be kept
in durable, easily cleanable containers that do not leak and do not absorb
liquids. Garbage and refuse shall be disposed of often enough to prevent the
development of odor and the attraction of insects and rodents. Sewage shall be
disposed of by means of a public sewage disposal system or a septic system, and
may not constitute a source of contamination of food, equipment, or utensils or
otherwise create an unsanitary condition or nuisance.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1).

Law
Implemented:
 SDCL 
34-12-13(1).

Rule 44:78:02:02 Cleaning procedures.

44:78:02:02. Cleaning
procedures.
 The facility shall develop written procedures for cleaning all
areas of the building. The building shall be maintained clean. Equipment and
supplies shall be available for proper cleaning and disinfecting and shall be
stored safely to protect the building occupants. Dustless methods shall be used
for cleaning.

 Written
procedures shall be developed for the cleaning and sanitizing of food service
equipment, countertops in the food production area, and dining room tables in
accordance with the registered product label.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13.

Law
Implemented:
 SDCL 
34-12-13.

Rule 44:78:02:03 Patient rooms.

44:78:02:03. Patient
rooms.
 A patient room shall meet the following requirements:

 (1) The
maximum room capacity is two patients. Patient rooms approved prior to January
1, 2001, are acceptable as approved;

 (2) The
minimum clear floor area required is, exclusive of toilet rooms, closets,
wardrobes, and vestibules, 100 square feet in single occupancy and 160 square
feet in double occupancy;

 (3) The
floor of the patient room shall be above grade at the building site;

 (4) A
separate closet space of five square feet shall be provided for each patient;
and

 (5) Toilet
rooms shall be available to the patient room. If the toilet room is not
attached to the patient room, the distance to the toilet room from the door to
the patient room may not exceed 50 feet. The toilet room shall be accessible
and shall contain a handwashing fixture and stool with at least a side grab bar
and toilet paper dispenser.

Source:
 
42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Rule 44:78:02:04 Patient room furnishings.

44:78:02:04. Patient
room furnishings.
 The facility shall provide the following furnishings for
the patient rooms:

 (1) A
sturdy, comfortable bed with an impervious cover on the mattress;

 (2) A
pillow, two sheets, blanket, and bath towel;

 (3) A
dresser, drawers, or shelves for each patient;

 (4) A
chair, table or desk, reading lamp, and mirror for each patient; and

 (5) Window
coverings for privacy.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3)
 and (4).

Law
Implemented:
 SDCL 
34-12-13(3)
 and (4).

Rule 44:78:02:05 Care units.

44:78:02:05. Care
units.
 The care unit shall contain the following features:

 (1) Staff
work area with handwashing fixture, charting space, communication and security
equipment, supply storage, and locked medication storage, including
refrigerated storage and dispensing area;

 (2) Staff
toilet room convenient to work area. The toilet room shall be accessible and
shall contain a handwashing fixture and stool with at least a side grab bar and
toilet paper dispenser;

 (3) Clean
linen storage or linen cart storage room;

 (4) A
housekeeping room for supply and housekeeping equipment storage. A floor
receptor or service sink shall be provided and the adjacent wall surfaces shall
be protected from water damage;

 (5) A
bathing room for each gender served with bath fixtures in accordance with SDCL 
36-25-15
 and 
36-25-15.1
;

 (6) Lounge
space with a minimum area of 20 square feet for each patient;

 (7) Dining
space with a minimum of 20 square feet for each patient;

 (8) A
group room with a minimum of 150 square feet for each six patients; and

 (9) A
counselor office with a minimum of 100 square feet for each six patients.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
, (3), (4), and (14).

Law
Implemented:
 SDCL 
34-12-13(1)
, (3), (4), and (14).

Rule 44:78:02:06 Food service.

44:78:02:06. Food
service.
 In-house dietary department areas and equipment shall meet
sanitary storage, processing, and handling requirements of the Food Service
Code. If a facility's food service is contracted out, the contractor shall be a
licensed food service establishment that is inspected by a local, state, or
federal agency. If the facility has an in-house dietary department the dietary
manager or at least one cook must successfully complete and possess a current
certificate from a ServSafe Food Protection Program offered by various
retailers or the Certified Food Protection Professional's Sanitation Course
offered by the Dietary Managers Association, or successfully completed
equivalent training as determined by the Health Department. If the facility
contracts out food services at least one staff person serving meals shall
successfully complete and possess a current certificate from a ServSafe Food
Protection Program or equivalent as noted in this section. The following
equipment and space shall be provided in the dietary area: 

 (1) A
receiving area for incoming food supplies;

 (2) A
vegetable preparation two compartment sink with a garbage disposal. This
fixture requires an indirect connection to the waste line;

 (3) A
dry food storage area;

 (4) A
floor receptor with moisture resistant protection for the adjacent wall
surfaces;

 (5) Refrigerated
storage space with 15 cubic foot refrigerator capacity and four cubic foot
freezer capacity for each 12 persons served by the dietary area. Refrigerated
storage for milk, eggs, and butter shall be located within six feet of the food
preparation areas;

 (6) Food
production equipment designed to produce a complete meal three times daily for
each person served;

 (7) Food
holding and transport equipment capable of protecting food from contamination
and maintaining safe temperatures during the meal serving time;

 (8) A
hood and ventilation equipment for cooking equipment to remove heat, moisture,
cooking odors, and grease to the exterior of the building. Continuous
mechanical exhaust ventilation at the commercial dishwasher location to remove
heat and moisture;

 (9) A
handwashing fixture convenient to food preparation areas and dishwashing. No
mirror is allowed at these sink locations;

 (10) Aisles
of 36 inches clear width;

 (11) If
a grease trap is required by local ordinance, it shall be located in a room
adjacent to the dietary area;

 (12) A
dishwasher with a sanitizing cycle. A commercial dishwasher supplied with 180
degree Fahrenheit rinse water or a chemical sanitizing cycle is required when
more than 20 meals are served;

 (13) Dietary
manager work space with desk and chair; and

 (14) A
self-dispensing ice machine. Ice from a bin type ice machine may be used for
cooling food containers, but not for consumption.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(5)
 and (8).

Law
Implemented:
 SDCL 
34-12-13(5)
 and (8).

Note:

Article 44:02, Lodging and Food Service, Administrative Rules of South Dakota,
contains the Food Service Code and may be obtained from Legislative Mail, 1320
East Sioux Avenue, Pierre, South Dakota 57501, telephone (605) 773-4935, for
$4.14.

Rule 44:78:02:07 Laundry.

44:78:02:07. Laundry.

Personal clothing shall be transported to the laundry equipment in a closed
container.

 The
facility shall process laundry following the laundry equipment and cleaning
agent recommendations. If hot water is used for disinfection, all common use
linens and combined patients' personal clothing shall be processed for
disinfection using either hot water at 160 degrees Fahrenheit (71 degrees
centigrade) or chlorine bleach shall be introduced to the process to provide
100 parts per million free chlorine with the water temperature reduced to 120
degrees Fahrenheit or department approved laundry disinfectant. Air flow in the
linen processing shall be from clean processing areas toward the soiled holding
and sorting area. Clean linens shall be covered during transport to storage
areas. Laundry services shall have adequate space and equipment for the safe
and effective operation of the laundry service.

 The
facility may choose to wash commingled patients' personal clothing, common-use
linen, and any isolation clothing in water temperatures less than 120 º F. if
the following conditions are met:

 (1) The
supplier of the chemical specifies low-temperature wash formulas in writing for
the machines used in the facility;

 (2) Charts
providing specific information concerning the formulas to be used for each
machine are posted in an area accessible to staff;

 (3) The
facility ensures that laundry staff receives in-service training by the
chemical supplier on a routine basis, regarding chemical usage and monitoring
of wash operations; and

 (4) The
facility ensures that staff monitors chemical usage and wash water temperatures
at least monthly to ensure conformance with the chemical supplier's
instructions.

 Any
resident's personal clothing that is not commingled may be processed according
to manufacturer's recommendations using water temperatures and detergent in
quantity as recommended by the garment or detergent manufacturer. The facility
shall have distinct areas for the storage and handling of clean and soiled
linens. Those areas used for the storage and handling of soiled linens shall be
negatively pressurized. The facility shall establish special procedures for the
handling and processing of contaminated linens. Soiled linen shall be placed in
closed containers prior to transportation. To safeguard clean linens from cross
contamination, the linens shall be transported in containers used exclusively
for clean linens, shall be kept covered with dust covers at all times while in
transit or in hallways, and shall be stored in areas designated exclusively for
this purpose. A written request for any modification of the requirements of
this section shall be received and approved by the department before any
changes are made.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
 and (4).

Law
Implemented:
 SDCL 
34-12-13(1)
 and (4).

Rule 44:78:02:08 Storage.

44:78:02:08. Storage.

A minimum of the 200 square feet of general supply storage shall be provided in
a single room. If the patient capacity exceeds 25, an additional 200 square
feet of storage shall be provided for each multiple of 25 patients.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Rule 44:78:02:09 Outside yard storage.

44:78:02:09. Outside
yard storage.
 The facility shall provide storage space for yard equipment
with an exterior building access or separate storage shed.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Rule 44:78:02:10 Flooring.

44:78:02:10. Flooring.

Flooring materials that are slip resistant shall be installed at the building
main entry, dishwashing, and bathing areas.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
 and (3).

Law
Implemented:
 SDCL 
34-12-13(1)
 and (3).

Rule 44:78:02:11 Handwashing fixtures.

44:78:02:11. Handwashing
fixtures.
 Hot and cold water shall be supplied through a mixing faucet
controlled by a "hands free" operator. Each handwashing fixture shall
be provided with a soap dispenser, hand dryers or protected single use towel
dispensers, and waste receptacle.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3)
 and (4).

Law
Implemented:
 SDCL 
34-12-13(3)
 and (4).

Rule 44:78:02:12 Exhaust ventilation.

44:78:02:12. Exhaust
ventilation.
 Electrically powered continuous exhaust ventilation shall be
provided for soiled areas, wet areas, and toilet rooms at ten air changes each
hour and shall be provided for storage rooms at two air changes each hour.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Rule 44:78:02:13 Waste disposal.

44:78:02:13. Waste
disposal.
 Garbage, refuse, and waste shall be handled and disposed of in a
safe and sanitary manner. Final disposal of all refuse and waste shall comply
with articles 74:27 and 74:28. Putrescible garbage shall be removed at a
frequency to contain or prevent odors, insects, and vermin.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1).

Law
Implemented:
 SDCL 
34-12-13(1).

Rule 44:78:02:14 Ventilation.

44:78:02:14. Ventilation.

The facility shall have general ventilation of two air changes each hour. The
outside air supply shall be tempered to eliminate cold air from being
introduced into occupied space. The supply air unit shall be equipped with one
inch furnace filter media installed in the ductwork ahead of the unit. The
filter media shall be changed at least every three months.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
 and (3).

Law
Implemented:
 SDCL 
34-12-13(1)
 and (3).

Rule 44:78:02:15 Heating and cooling.

44:78:02:15. Heating
and cooling.
 The facility heating system shall be capable of maintaining a
minimum temperature of 75 degrees Fahrenheit at winter design conditions. The
building cooling system shall be capable of maintaining room temperatures in
occupied spaces at 75 degrees Fahrenheit or less.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Rule 44:78:02:16 Hot water systems.

44:78:02:16. Hot
water systems.
 The facility shall install a recirculating system to provide
hot water to all fixtures. Equipment shall be installed to provide hot water at
a temperature of 100 (38 degrees centigrade) to 125 degrees Fahrenheit (52
degrees centigrade) to all handwashing sinks. Maximum hot water temperatures at
plumbing fixtures used by patients may not exceed 125 degrees Fahrenheit (52
degrees centigrade).

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
 and (3).

Law
Implemented:
 SDCL 
34-12-13(1)
 and (3).

Rule 44:78:02:17 Potable water.

44:78:02:17. Potable
water.
 All plumbing used for distribution of potable water shall be
maintained to minimize dead-end runs of piping. Before placing a potable water
system into use and after repairs or modifications, the system shall be
disinfected in accordance with the 2009 Uniform Plumbing Code, Section 609.9.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
 and (3).

Law
Implemented:
 SDCL 
34-12-13(1)
 and (3).

Rule 44:78:02:18 Water supply.

44:78:02:18. Water
supply.
 The facility's water supply shall be obtained from a public water
system or, in its absence, from a supply approved by the Department of 
Agriculture
 and Natural
Resources. Any private water supply shall have a water sample bacteriologically
tested at least monthly. The volume of water shall be sufficient for the needs
of the facility. The hot water system shall be capable of supplying the work
and resident areas with water at the required temperatures.

Source:

42 SDR 51, effective October 13, 2015
; SL 2021, ch 1, §§ 8, 19, effective April
19, 2021
.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Rule 44:78:02:19 Plumbing.

44:78:02:19. Plumbing.

A facility's plumbing system shall be designed and installed in accordance with
SDCL 
36-25-15
 and 
36-25-15.1.
 Plumbing shall be sized, installed, and
maintained to carry required quantities of water to required locations
throughout the facility.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Rule 44:78:02:20 Lighting.

44:78:02:20. Lighting.

All building spaces, parking lots, and exit discharge routes shall be
illuminated for general safety. Specific required lighting levels shall be
provided for the following spaces:

 (1) Ten
footcandles for general illumination;

 (2) Thirty
footcandles for dining rooms, bathing areas, food preparation areas, laundry,
staff work area, and areas where persons are involved in reading or other close
work tasks;

 (3) Fifty
footcandles shall be provided on the work surface of the medication set up and
distribution area; and

 (4) Portable
halogen lamps may not be used due to extremely high surface temperatures.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
 and (3).

Law
Implemented:
 SDCL 
34-12-13(1)
 and (3).

Rule 44:78:02:21 Electrical convenience outlets.

44:78:02:21. Electrical
convenience outlets.
 Electrical extension cords may not be used as a
substitute for properly installed electrical receptacles. Power strips in
business office areas and for entertainment centers may be used.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Rule 44:78:02:22 Infection control.

44:78:02:22. Infection
control.
 The facility shall develop policies to address cleaning of
environmental surfaces, standard precautions, employee illness, and patient
transfer to another health care facility.

 Chemicals
used to sanitize, disinfect, or sterilize shall be labeled to show registration
with the United States Environmental Protection Agency as being safe and
effective for use in accordance with the procedures used by the facility.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
 and (2).

Law
Implemented:
 SDCL 
34-12-13(1)
 and (2).

Rule 44:78:02:23 Occupant protection.

44:78:02:23. Occupant
protection.
 Each facility shall be constructed, arranged, equipped,
maintained, and operated to avoid injury or danger to the occupants. The extent
and complexity of occupant protection precautions is determined by the services
offered and the physical needs of the patients admitted to the facility. The
facility shall take at least the following precautions:

 (1) Provide
securely constructed and conveniently located grab bars in all toilet rooms and
bathing areas used by patients;

 (2) Provide
grounded or double-insulated electrical equipment or protect the equipment with
ground fault circuit interrupters. Ground fault circuit interrupters shall be
provided in wet areas and for outlets within six feet of sinks;

 (3) 
A portable space heater, portable halogen lamp, household-type electric blanket
or household-type heating pad may not be used in a facility;

 (4) Any
clothes dryer shall have a galvanized metal vent pipe for exhaust; and

 (5) The
storage and transfilling of oxygen cylinders or containers shall meet the
requirements of the NFPA 99 Standard for Health Care Occupancies, 2012 Edition.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
 and (3).

Law
Implemented:
 SDCL 
34-12-13(1)
 and (3).

Reference:
NFPA 99 Health Care Facilities
, 2012 edition, National Fire Protection
Association. Copies may be obtained from the National Fire Protection
Association, P.O. Box 9101, Quincy, MA 02269-9101. Phone: 1-800-344-3555. Cost:
$93.00.

Rule 44:78:02:24 Physical plant changes.

44:78:02:24. Physical
plant changes.
 A facility shall submit any proposed change by new
construction, remodeling, or change of use of an area to the department. Any
change shall have the approval of the department before it is made. A written
narrative describing the intended use of the proposed construction shall
accompany the plans and specifications.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
 and (3).

Law
Implemented:
 SDCL 
34-12-13(1)
 and (3).

Rule 44:78:02:25 Insect and rodent control.

44:78:02:25. Insect
and rodent control.
 The facility shall take measures to effectively control
the entry, presence, and breeding of vermin. All openings around pipe, conduit,
and wiring or similar penetrations of the exterior wall shall be caulked to prevent
vermin entry. Any poisons used shall be stored safely to avoid contamination of
food and properly labeled and applied to protect the building occupants.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1).

Law
Implemented:
 SDCL 
34-12-13(1).

Rule 44:78:02:26 Location.

44:78:02:26. Location.

The location of the facility shall promote the health, treatment, comfort,
safety, and well-being of persons accepted and retained for care. The facility
shall be served by good, passable roads. Easy accessibility for caregivers, visitors,
and fire-fighting services shall be maintained.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
, (3), and (14).

Law
Implemented:
 SDCL 
34-12-13(1)
, (3), and (14).

Rule 44:78:02:27 Preventative maintenance.

44:78:02:27. Preventative
maintenance.
 The facility shall develop and implement a written system of
scheduled maintenance for building equipment, mechanical, and electrical
systems.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1).

Law
Implemented:
 SDCL 
34-12-13(1).

Rule 44:78:02:28 Other hazardous conditions.

44:78:02:28. Other
hazardous conditions.
 A facility may be directed to remove or correct other
hazardous conditions not covered in this chapter if the department considers
the conditions to have the potential to cause injury or illness to any resident
or staff.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(1)
 and (14).

Law
Implemented:
 SDCL 
34-12-13(1)
 and (14).

Rule 44:78:02:29 Personnel training.

44:78:02:29. Personnel
training.
 The facility shall have a formal orientation program and an
ongoing education program for all personnel. Ongoing education programs shall
cover the required subjects annually. These programs shall include the
following subjects:

 (1) Fire
prevention and response. The facility shall conduct fire drills quarterly for
each shift. If the facility is not operating with three shifts, monthly fire
drills shall be conducted to provide training for all staff;

 (2) Emergency
procedures and preparedness;

 (3) Infection
control and prevention;

 (4) Accident
prevention and safety procedures; and

 (5) Incidents
and diseases subject to mandatory reporting and the facility's reporting
mechanisms;

 Additional
personnel education shall be based on facility identified needs.

 Current
professional and technical reference books and periodicals shall be made
available for personnel.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(5).

Law
Implemented:
 SDCL 
34-12-13(5).

CHAPTER

44:78:03

FIRE SAFETY AND
CONSTRUCTION STANDARDS

Section

44:78:03:01
 Fire
safety code requirements.

44:78:03:02
 General
fire safety.

44:78:03:03
 Staffing
exception.

44:78:03:04
 Fire
extinguishers.

44:78:03:05
 New
construction.

Rule 44:78:03:01 Fire safety code requirements.

44:78:03:01. Fire
safety code requirements.
 Each facility shall meet applicable fire safety
standards in 
NFPA 101 Life Safety Code
, 2000 edition. An automatic
sprinkler system is not required in an existing facility unless significant
renovations or remodeling occurs; however, any existing automatic sprinkler
system shall remain in service.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Reference:
NFPA 101 Life Safety Code
, 2000 edition, National Fire Protection
Association. Copies may be obtained from the National Fire Protection
Association, P.O. Box 9101, Quincy, Massachusetts 02269-9101. Phone:
1-800-344-3555. Cost: $93.00.

Rule 44:78:03:02 General fire safety.

44:78:03:02. General
fire safety.
 Each facility covered under this article shall be constructed,
arranged, equipped, maintained, and operated to avoid undue danger to the lives
and safety of its occupants from fire, smoke, fumes, or resulting panic during
the period of time reasonably necessary for escape from the structure in case
of fire or other emergency. The fire alarm system shall be sounded each month.
At least two staff members shall be on duty at all times. In a multilevel
facility, at least one staff member shall be on duty on each floor containing
occupied beds. Compliance with this section does not eliminate or reduce the
necessity for other provisions for safety of persons using the structure under
normal occupancy conditions.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Cross-Reference:

Fire safety code requirements, § 44:78:03:01.

Rule 44:78:03:03 Staffing exception.

44:78:03:03. Staffing
exception.
 A staffing exception may be allowed as follows:

 (1) For
each facility with 16 beds or less, one staff person who is awake is required
if:

 (a) The
facility fire alarm promptly alerts staff;

 (b) The
facility is equipped with an automatic sprinkler system as defined in § 9.7,
automatic sprinklers, of 
NFPA 101 Life Safety Code
, 2000 edition;

 (c) An
automatic fire alarm dialer as defined in § 9.6.4, Emergency Forces
Notification, of 
NFPA 101 Life Safety Code
, 2000 edition, to summon the
local fire department is provided; and

 (d) The
clients have an evacuation time which shows them capable of evacuation in five
minutes or less.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Reference:
NFPA 101 Life Safety Code
, 2000 edition, National Fire Protection
Association. Copies may be obtained from the National Fire Protection
Association, P.O. Box 9101, Quincy, Massachusetts 02269-9101. Phone: 1-800-344-3555.
Cost: $93.00.

Rule 44:78:03:04 Fire extinguishers.

44:78:03:04. Fire
extinguishers.
 Fire extinguishers that are at least 2-A:10-B:C rated shall
be installed for general building coverage at a rate of one for each 3,000
square feet and one additional 2-A:10-B:C rated extinguisher also located at
the kitchen, laundry, and furnace room.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Rule 44:78:03:05 New construction.

44:78:03:05. 
New Construction.
 The provisions of this section apply to each newly
licensed inpatient chemical dependency treatment facility and to any
renovation, addition, or change in space use of currently approved existing
facility.

 Each
new construction, renovation, addition, and change of space use shall comply
with Article 44:78 and NFPA 101 Life Safety Code, 2012 edition.

Source:

42 SDR 51, effective October 13, 2015.

General
Authority:
 SDCL 
34-12-13(3).

Law
Implemented:
 SDCL 
34-12-13(3).

Reference:
NFPA 101 Life Safety Code
, 2012 edition, National Fire Protection
Association. Copies may be obtained from the National Fire Protection
Association, P.O. Box 9101, Quincy, MA 02269-9101. Phone: 1-800-344-3555. Cost:
$93.00.